ActiveXperts Knowledge Base Article 6830040
After the upgrade ActiveXperts Network Monitor to the latest version, some Sensatronics devices cannot be monitored, reporting "Unable to connect; no response received from remote server", even though the device can be pinged.
The reason for this problem is the fact that ActiveXperts uses the WinHTTP library of the Operating System. In v.7 and older, ActiveXperts used a separate WinHTTP5 library (not part of the OS). The WinHTTP library of a recent operating systems do NOT support HTTP0.9 anymore. And some Sensatronics models with older firmware have a HTTP0.9 web server inside.
To fix the problem, perform the following steps:
- Open the Registry Editor (REGEDIT.EXE)
- Open HKLM\Software\ActiveXperts\Network Monitor\Sensatronics\ and set Http09CompatibilityFlag to 1
- Quit the the ActiveXperts Network Monitor Manager application
- Restart the ActiveXperts Network Monitor Engine service
NOTE: If the registry entry 'Http09CompatibilityFlag' is NOT there, start the Manager application in Administrator modus ('Run As Administrator') and create a new EM1 check once more. Make sure you query the device in the configuration window. Now, the 'Http09CompatibilityFlag' should be there.
Contact Support
If you cannot find an answer to your question(s) in our Knowledge Base, or if you need additional information or assistance, please contact our Customer Support using the Contact Support form:
Contact Support »