Serial.vbs - Monitor a Serial Device like a modem or a UPS connected to a COM port
ActiveXperts Network Monitor ships with a powerful set of pre-defined checks. Each individual check has a static number of configuration items. To monitor other items, or to combine monitoring items, you can make use of custom VBScript checks.
Most of the built-in checks have a VBScript equivalent, implemented as a Function in a VBScript (.vbs) file. Out-of-the-box, each VBScript function monitors the same items as the built-in check. Feel free to modify a function. The VBScript check can be customized by editing the VBScript function.
To add a new VBScript-based Serial Device monitoring check, do the following:
- On the 'Monitor menu', click 'New Monitoring Check (VBScript)'. The 'VBScript Check' dialog box appears;
- In the 'File selection box', select 'Serial.vbs';
- In the 'Function selection box', select 'CheckSerialDevice';
- In the 'Function parameters group box' enter the required parameters. You can also load a working sample first by clicking on the 'Load a sample, click here' link.
To customize the above monitoring check, click on the 'Edit button' next to the 'File selection box'. Notepad will be launched. You can now make changes to the VBScript function(s).

Serial.vbs script source code
' /////////////////////////////////////////////////////////////////////////////// ' // ActiveXperts Network Monitor - VBScript based checks ' // © ActiveXperts Software B.V. ' // ' // For more information about ActiveXperts Network Monitor and VBScript, please ' // visit the online ActiveXperts Network Monitor VBScript Guidelines at: ' // https://www.activexperts.com/support/network-monitor/online/vbscript/ ' // ' /////////////////////////////////////////////////////////////////////////////// ' Option Explicit Const retvalUnknown = 1 Dim SYSDATA, SYSEXPLANATION ' Used by Network Monitor, don't change the names ' /////////////////////////////////////////////////////////////////////////////// ' // To test a function outside Network Monitor (e.g. using CSCRIPT from the ' // command line), remove the comment character (') in the following 5 lines: ' Dim bResult ' bResult = CheckSerialDevice( "COM1" ) ' WScript.Echo "Return value: [" & bResult & "]" ' WScript.Echo "SYSDATA: [" & SYSDATA & "]" ' WScript.Echo "SYSEXPLANATION: [" & SYSEXPLANATION & "]" ' ////////////////////////////////////////////////////////////////////////////// ' ////////////////////////////////////////////////////////////////////////////// Function CheckSerialDevice( strDevice ) ' Description: ' Queries a serial device. Depending on the results, the result is set to True, ' False or Unknown ' Parameters: ' 1) strDevice As String - COM port (like: COM1) or TAPI Device (like: Standard 9600 bps Modem) ' Usage: ' CheckSerialDevice( "" ) ' Sample: ' CheckSerialDevice( "COM1" ) Dim objComport, strResponse, strResponseAll, iResponse Set objComport = CreateObject( "AxSerial.ComPort" ) ' Set Device property objComport.Device = strDevice ' Optionally, override device defaults ' objComport.BaudRate = 57600 ' objComport.HardwareFlowControl = True ' objComport.SoftwareFlowControl = False ' Optionally, set Logging - for troubleshooting purposes ' objComport.LogFile = "C:\AxSerialPort.log" ' Open the device objComport.Open If( objComport.LastError <> 0 ) Then CheckSerialDevice = retvalUnknown SYSEXPLANATION = "Open port failed, Error #" & objComport.LastError & ": " & objComport.GetErrorDescription( objComport.LastError ) Exit Function End If ' Write command: "ATZ" objComport.WriteString "ATZ" If( objComport.LastError <> 0 ) Then CheckSerialDevice = retvalUnknown SYSEXPLANATION = "Write port failed, Error #" & objComport.LastError & ": " & objComport.GetErrorDescription( objComport.LastError ) objComport.Close Exit Function End If ' Wait for the response (expected response: "OK") strResponseAll = "[" & objComport.ReadString & "]" If( objComport.LastError <> 0 ) Then CheckSerialDevice = retvalUnknown SYSEXPLANATION = "Read port failed, Error #" & objComport.LastError & ": " & objComport.GetErrorDescription( objComport.LastError ) objComport.Close Exit Function End If iResponse = 1 While( objComport.LastError = 0 And iResponse < 10 ) strResponse = "[" & objComport.ReadString & "]" If( objComport.LastError = 0 ) Then strResponseAll = strResponseAll & " " & strResponse End If iResponse = iResponse + 1 WEnd If( InStr( UCase( strResponseAll ), "OK" ) ) Then CheckSerialDevice = True SYSEXPLANATION = "Response matched, response=" & strResponseAll Else CheckSerialDevice = False SYSEXPLANATION = "Response not matched, response=" & strResponseAll End If ' Close the port objComport.Close Set objComport = Nothing End Function