MsIisServer.vbs - Microsoft IIS Internet Information Server monitoring using ActiveXperts Network Monitor
ActiveXperts Network Monitor ships with a powerful set of pre-defined checks. Each individual check has a static number of configuration items. To monitor other items, or to combine monitoring items, you can make use of custom VBScript checks.
Most of the built-in checks have a VBScript equivalent, implemented as a Function in a VBScript (.vbs) file. Out-of-the-box, each VBScript function monitors the same items as the built-in check. Feel free to modify a function. The VBScript check can be customized by editing the VBScript function.
To add a new VBScript-based Microsoft Internet Information Server monitoring check, do the following:
- On the 'Monitor menu', click 'New Monitoring Check (VBScript)'. The 'VBScript Check' dialog box appears;
- In the 'File selection box', select 'MsIisServer.vbs';
- In the 'Function selection box', select 'CheckIisServer';
- In the 'Function parameters group box' enter the required parameters. You can also load a working sample first by clicking on the 'Load a sample, click here' link.
To customize the above monitoring check, click on the 'Edit button' next to the 'File selection box'. Notepad will be launched. You can now make changes to the VBScript function(s).

MsIisServer.vbs script source code
' /////////////////////////////////////////////////////////////////////////////// ' // ActiveXperts Network Monitor - VBScript based checks ' // (c) ActiveXperts Software B.V. ' // ' // For more information about ActiveXperts Network Monitor and VBScript, please ' // visit the online ActiveXperts Network Monitor VBScript Guidelines at: ' // https://www.activexperts.com/support/network-monitor/online/vbscript/ ' /////////////////////////////////////////////////////////////////////////////// Option Explicit Const retvalUnknown = 1 Dim SYSDATA, SYSEXPLANATION ' Used by Network Monitor, don't change the names ' /////////////////////////////////////////////////////////////////////////////// ' // To test a function outside Network Monitor (e.g. using CSCRIPT from the ' // command line), remove the comment character (') in the following 5 lines: ' Dim bResult ' bResult = CheckIisServer( "localhost", "" ) ' WScript.Echo "Return value: [" & bResult & "]" ' WScript.Echo "SYSDATA: [" & SYSDATA & "]" ' WScript.Echo "SYSEXPLANATION: [" & SYSEXPLANATION & "]" ' ////////////////////////////////////////////////////////////////////////////// Function CheckIisServer( strComputer, strCredentials ) ' Description: ' Checks if IIS Server is running; it checks the IIS services and IIS processes ' Parameters: ' 1) strComputer As String - Hostname or IP address of the server you want to check ' 2) strCredentials As String - Specify an empty string to use Network Monitor service credentials. ' To use alternate credentials, enter a server that is defined in Server Credentials table. ' (To define Server Credentials, choose Tools->Options->Server Credentials) ' Usage: ' CheckIisServer( "<Hostname | IP>", "<Empty String | Server>" ) ' Sample: ' CheckIisServer( "localhost", "" ) Dim objWMIService, lstServices, numResult CheckIisServer = retvalUnknown ' Default return value SYSDATA = "" ' Not used by this function SYSEXPLANATION = "" ' Set initial value ' Get thew WMI object If( Not getWMIObject( strComputer, strCredentials, objWMIService, SYSEXPLANATION ) ) Then Exit Function End If numResult = checkIisServices( objWMIService, strComputer, SYSEXPLANATION ) If( numResult <> True ) Then CheckIisServer = numResult Exit Function End If numResult = checkIisProcesses( objWMIService, strComputer, SYSEXPLANATION ) If( numResult <> True ) Then CheckIisServer = numResult Exit Function End If CheckIisServer = True SYSEXPLANATION = "All conditions are met" End Function ' ////////////////////////////////////////////////////////////////////////////// ' // ' // Private Functions ' // NOTE: Private functions are used by the above functions, and will not ' // be called directly by the ActiveXperts Network Monitor Service. ' // Private function names start with a lower case character and will ' // not be listed in the Network Monitor's function browser. ' // ' ////////////////////////////////////////////////////////////////////////////// Function checkIisServices( objWMIService, strComputer, BYREF strSysExplanation ) Dim result, lstServices checkIisServices = retvalUnknown strSysExplanation = "" ' Get the services list If( Not retrieveServicesList( objWMIService, strComputer, lstServices, SYSEXPLANATION ) ) Then Exit Function End If result = isServiceRunning( lstServices, "IISADMIN", "IIS Admin Service", strSysExplanation ) If( result = True ) Then result = isServiceRunning( lstServices, "W3SVC", "World Wide Web Publishing Service", strSysExplanation ) End If checkIisServices = result End Function ' ////////////////////////////////////////////////////////////////////////////// Function checkIisProcesses( objWMIService, strComputer, BYREF strSysExplanation ) Dim result checkIisProcesses = retvalUnknown strSysExplanation = "" result = isProcessRunning( objWMIService, strComputer, "inetinfo.exe", strSysExplanation ) ' If( result = True ) Then ' result = isProcessRunning( objWMIService, strComputer, "myprocess.exe", strSysExplanation ) ' End If checkIisProcesses = result End Function ' ////////////////////////////////////////////////////////////////////////////// Function retrieveServicesList( objWMIService, strComputer, BYREF lstServices, BYREF strSysExplanation ) ' Retrieve the list of running services retrieveServicesList = False Set lstServices = Nothing Set lstServices = objWMIService.ExecQuery( "Select * from Win32_Service WHERE state = ""Running""" ) If( Err.Number <> 0 ) Then strSysExplanation = "Unable to query WMI on computer [" & strComputer & "]" Exit Function End If If( lstServices.Count <= 0 ) Then strSysExplanation = "Win32_Service class does not exist on computer [" & strComputer & "]" Exit Function End If On Error Goto 0 retrieveServicesList = True End Function ' ////////////////////////////////////////////////////////////////////////////// Function isServiceRunning( BYREF lstServices, strServiceName, strServiceDescription, BYREF strSysExplanation ) ' Check if a given service exists as running service in the services list Dim objService isServiceRunning = False ' Default return value For Each objService in lstServices If( Err.Number <> 0 ) Then isServiceRunning = retvalUnknown strSysExplanation = "Unable to list services" Exit Function End If ' Check If this is the service we are looking for If( LCase( objService.Name ) = LCase( strServiceName ) ) Then isServiceRunning = True Exit Function End If Next ' The service was not found, show an error message strSysExplanation = "'" & strServiceDescription & "' service is not running" isServiceRunning = False End Function ' ////////////////////////////////////////////////////////////////////////////// Function isProcessRunning( objWMIService, strComputer, strProcess, BYREF strSysExplanation ) Dim objProcess, collProcesses isProcessRunning = retvalUnknown ' Default return value On Error Resume Next set collProcesses = objWMIService.ExecQuery( "select * from Win32_Process" ) If( Err.Number <> 0 ) Then strSysData = "" strSysExplanation = "Unable to query WMI on computer [" & strComputer & "]" Exit Function End If If( collProcesses.Count <= 0 ) Then strSysData = "" strSysExplanation = "Win32_Process class does not exist on computer [" & strComputer & "]" Exit Function End If On Error Goto 0 For Each objProcess in collProcesses If( Err.Number <> 0 ) Then isProcessRunning = retvalUnknown strSysExplanation = "Unable to list processes on computer [" & strComputer & "]" Exit Function End If If UCase( objProcess.Name ) = UCase( strProcess ) Then isProcessRunning = True strSysExplanation = "Process [" & strProcess & "] is running on computer [" & strComputer & "]" Exit Function End If Next isProcessRunning = False strSysExplanation = "Process [" & strProcess & "] is not running on computer [" & strComputer & "]" End Function ' ////////////////////////////////////////////////////////////////////////////// Function getWMIObject( strComputer, strCredentials, BYREF objWMIService, BYREF strSysExplanation ) On Error Resume Next Dim objNMServerCredentials, objSWbemLocator, colItems Dim strUsername, strPassword getWMIObject = False Set objWMIService = Nothing If( strCredentials = "" ) Then ' Connect to remote host on same domain using same security context Set objWMIService = GetObject( "winmgmts:{impersonationLevel=Impersonate}!\\" & strComputer &"\root\cimv2" ) Else Set objNMServerCredentials = CreateObject( "ActiveXperts.NMServerCredentials" ) strUsername = objNMServerCredentials.GetLogin( strCredentials ) strPassword = objNMServerCredentials.GetPassword( strCredentials ) If( strUsername = "" ) Then getWMIObject = False strSysExplanation = "No alternate credentials defined for [" & strCredentials & "]. In the Manager application, select 'Options' from the 'Tools' menu and select the 'Server Credentials' tab to enter alternate credentials" Exit Function End If ' Connect to remote host using different security context and/or different domain Set objSWbemLocator = CreateObject( "WbemScripting.SWbemLocator" ) Set objWMIService = objSWbemLocator.ConnectServer( strComputer, "root\cimv2", strUsername, strPassword ) If( Err.Number <> 0 ) Then objWMIService = Nothing getWMIObject = False strSysExplanation = "Unable to access [" & strComputer & "]. Possible reasons: WMI not running on the remote server, Windows firewall is blocking WMI calls, insufficient rights, or remote server down" Exit Function End If objWMIService.Security_.ImpersonationLevel = 3 End If If( Err.Number <> 0 ) Then objWMIService = Nothing getWMIObject = False strSysExplanation = "Unable to access '" & strComputer & "'. Possible reasons: no WMI installed on the remote server, no rights to access remote WMI service, or remote server down" Exit Function End If getWMIObject = True End Function