TeredoServer - WMI sample in VBScript
The foundations for Manageability in Windows 2019/2012/2008/ and Windows 10/8/7/Vista/XP are Windows Management Instrumentation (WMI; formerly WBEM) and WMI extensions for Windows Driver Model (WDM).
ActiveXperts Network Monitor provides the ability to build monitor check routines based on WMI. ActiveXperts has collected more than a hundred WMI samples. You can use these samples as a base for new check routines you can write yourself.
On this site, you can find many WMI samples.
The TeredoServer WMI class can be used in ActiveXperts Network Monitor to monitor your servers.
TeredoServer
Example(s)
Set objWMIService = GetObject("winmgmts:\\.\root\cimv2") Set colItems = objWMIService.ExecQuery("Select * From Win32_PerfRawData_Counters_TeredoServer") For Each objItem in colItems WScript.Echo "Caption:" & objItem.Caption WScript.Echo "Description:" & objItem.Description WScript.Echo "Frequency_Object:" & objItem.Frequency_Object WScript.Echo "Frequency_PerfTime:" & objItem.Frequency_PerfTime WScript.Echo "Frequency_Sys100NS:" & objItem.Frequency_Sys100NS WScript.Echo "InTeredoServerErrorPacketsAuthenticationError:" & objItem.InTeredoServerErrorPacketsAuthenticationError WScript.Echo "InTeredoServerErrorPacketsDestinationError:" & objItem.InTeredoServerErrorPacketsDestinationError WScript.Echo "InTeredoServerErrorPacketsHeaderError:" & objItem.InTeredoServerErrorPacketsHeaderError WScript.Echo "InTeredoServerErrorPacketsSourceError:" & objItem.InTeredoServerErrorPacketsSourceError WScript.Echo "InTeredoServerErrorPacketsTotal:" & objItem.InTeredoServerErrorPacketsTotal WScript.Echo "InTeredoServerSuccessPacketsBubbles:" & objItem.InTeredoServerSuccessPacketsBubbles WScript.Echo "InTeredoServerSuccessPacketsEcho:" & objItem.InTeredoServerSuccessPacketsEcho WScript.Echo "InTeredoServerSuccessPacketsRSPrimary:" & objItem.InTeredoServerSuccessPacketsRSPrimary WScript.Echo "InTeredoServerSuccessPacketsRSSecondary:" & objItem.InTeredoServerSuccessPacketsRSSecondary WScript.Echo "InTeredoServerSuccessPacketsTotal:" & objItem.InTeredoServerSuccessPacketsTotal WScript.Echo "InTeredoServerTotalPacketsSuccessError:" & objItem.InTeredoServerTotalPacketsSuccessError WScript.Echo "InTeredoServerTotalPacketsSuccessErrorPersec:" & objItem.InTeredoServerTotalPacketsSuccessErrorPersec WScript.Echo "Name:" & objItem.Name WScript.Echo "OutTeredoServerRAPrimary:" & objItem.OutTeredoServerRAPrimary WScript.Echo "OutTeredoServerRASecondary:" & objItem.OutTeredoServerRASecondary WScript.Echo "Timestamp_Object:" & objItem.Timestamp_Object WScript.Echo "Timestamp_PerfTime:" & objItem.Timestamp_PerfTime WScript.Echo "Timestamp_Sys100NS:" & objItem.Timestamp_Sys100NS WScript.Echo "" WScript.Echo "########" WScript.Echo "" Next