Contact Info

Crumbtrail

ActiveXperts.com » Administration » Scripts » WMI Performance Counters » VBScript

RASPort - WMI sample in VBScript

The foundations for Manageability in Windows 2019/2012/2008/ and Windows 10/8/7/Vista/XP are Windows Management Instrumentation (WMI; formerly WBEM) and WMI extensions for Windows Driver Model (WDM).

ActiveXperts Network Monitor provides the ability to build monitor check routines based on WMI. ActiveXperts has collected more than a hundred WMI samples. You can use these samples as a base for new check routines you can write yourself.

On this site, you can find many WMI samples.

The RASPort WMI class can be used in ActiveXperts Network Monitor to monitor your servers.


RASPort

Example(s)

Set objWMIService = GetObject("winmgmts:\\.\root\cimv2")

Set colItems = objWMIService.ExecQuery("Select * From Win32_PerfFormattedData_RemoteAccess_RASPort")

For Each objItem in colItems
	WScript.Echo "AlignmentErrors:" & objItem.AlignmentErrors
	WScript.Echo "BufferOverrunErrors:" & objItem.BufferOverrunErrors
	WScript.Echo "BytesReceived:" & objItem.BytesReceived
	WScript.Echo "BytesReceivedPerSec:" & objItem.BytesReceivedPerSec
	WScript.Echo "BytesTransmitted:" & objItem.BytesTransmitted
	WScript.Echo "BytesTransmittedPerSec:" & objItem.BytesTransmittedPerSec
	WScript.Echo "Caption:" & objItem.Caption
	WScript.Echo "CRCErrors:" & objItem.CRCErrors
	WScript.Echo "Description:" & objItem.Description
	WScript.Echo "FramesReceived:" & objItem.FramesReceived
	WScript.Echo "FramesReceivedPerSec:" & objItem.FramesReceivedPerSec
	WScript.Echo "FramesTransmitted:" & objItem.FramesTransmitted
	WScript.Echo "FramesTransmittedPerSec:" & objItem.FramesTransmittedPerSec
	WScript.Echo "Frequency_Object:" & objItem.Frequency_Object
	WScript.Echo "Frequency_PerfTime:" & objItem.Frequency_PerfTime
	WScript.Echo "Frequency_Sys100NS:" & objItem.Frequency_Sys100NS
	WScript.Echo "Name:" & objItem.Name
	WScript.Echo "PercentCompressionIn:" & objItem.PercentCompressionIn
	WScript.Echo "PercentCompressionOut:" & objItem.PercentCompressionOut
	WScript.Echo "SerialOverrunErrors:" & objItem.SerialOverrunErrors
	WScript.Echo "TimeoutErrors:" & objItem.TimeoutErrors
	WScript.Echo "Timestamp_Object:" & objItem.Timestamp_Object
	WScript.Echo "Timestamp_PerfTime:" & objItem.Timestamp_PerfTime
	WScript.Echo "Timestamp_Sys100NS:" & objItem.Timestamp_Sys100NS
	WScript.Echo "TotalErrors:" & objItem.TotalErrors
	WScript.Echo "TotalErrorsPerSec:" & objItem.TotalErrorsPerSec
	WScript.Echo ""
	WScript.Echo "########"
	WScript.Echo ""
Next