Contact Info

Crumbtrail

ActiveXperts.com » Administration » Scripts » WMI Performance Counters » VBScript

DiskDrive - WMI sample in VBScript

The foundations for Manageability in Windows 2019/2012/2008/ and Windows 10/8/7/Vista/XP are Windows Management Instrumentation (WMI; formerly WBEM) and WMI extensions for Windows Driver Model (WDM).

ActiveXperts Network Monitor provides the ability to build monitor check routines based on WMI. ActiveXperts has collected more than a hundred WMI samples. You can use these samples as a base for new check routines you can write yourself.

On this site, you can find many WMI samples.

The DiskDrive WMI class can be used in ActiveXperts Network Monitor to monitor your servers.


DiskDrive

Example(s)

Set objWMIService = GetObject("winmgmts:\\.\root\cimv2")

Set colItems = objWMIService.ExecQuery("Select * From CIM_DiskDrive")

For Each objItem in colItems
	WScript.Echo "Availability:" & objItem.Availability
	WScript.Echo "BytesPerSector:" & objItem.BytesPerSector
	WScript.Echo "Capabilities:" & objItem.Capabilities
	WScript.Echo "CapabilityDescriptions:" & objItem.CapabilityDescriptions
	WScript.Echo "Caption:" & objItem.Caption
	WScript.Echo "CompressionMethod:" & objItem.CompressionMethod
	WScript.Echo "ConfigManagerErrorCode:" & objItem.ConfigManagerErrorCode
	WScript.Echo "ConfigManagerUserConfig:" & objItem.ConfigManagerUserConfig
	WScript.Echo "CreationClassName:" & objItem.CreationClassName
	WScript.Echo "DefaultBlockSize:" & objItem.DefaultBlockSize
	WScript.Echo "Description:" & objItem.Description
	WScript.Echo "DeviceID:" & objItem.DeviceID
	WScript.Echo "ErrorCleared:" & objItem.ErrorCleared
	WScript.Echo "ErrorDescription:" & objItem.ErrorDescription
	WScript.Echo "ErrorMethodology:" & objItem.ErrorMethodology
	WScript.Echo "FirmwareRevision:" & objItem.FirmwareRevision
	WScript.Echo "Index:" & objItem.Index
	WScript.Echo "InstallDate:" & objItem.InstallDate
	WScript.Echo "InterfaceType:" & objItem.InterfaceType
	WScript.Echo "LastErrorCode:" & objItem.LastErrorCode
	WScript.Echo "Manufacturer:" & objItem.Manufacturer
	WScript.Echo "MaxBlockSize:" & objItem.MaxBlockSize
	WScript.Echo "MaxMediaSize:" & objItem.MaxMediaSize
	WScript.Echo "MediaLoaded:" & objItem.MediaLoaded
	WScript.Echo "MediaType:" & objItem.MediaType
	WScript.Echo "MinBlockSize:" & objItem.MinBlockSize
	WScript.Echo "Model:" & objItem.Model
	WScript.Echo "Name:" & objItem.Name
	WScript.Echo "NeedsCleaning:" & objItem.NeedsCleaning
	WScript.Echo "NumberOfMediaSupported:" & objItem.NumberOfMediaSupported
	WScript.Echo "Partitions:" & objItem.Partitions
	WScript.Echo "PNPDeviceID:" & objItem.PNPDeviceID
	WScript.Echo "PowerManagementCapabilities:" & objItem.PowerManagementCapabilities
	WScript.Echo "PowerManagementSupported:" & objItem.PowerManagementSupported
	WScript.Echo "SCSIBus:" & objItem.SCSIBus
	WScript.Echo "SCSILogicalUnit:" & objItem.SCSILogicalUnit
	WScript.Echo "SCSIPort:" & objItem.SCSIPort
	WScript.Echo "SCSITargetId:" & objItem.SCSITargetId
	WScript.Echo "SectorsPerTrack:" & objItem.SectorsPerTrack
	WScript.Echo "SerialNumber:" & objItem.SerialNumber
	WScript.Echo "Signature:" & objItem.Signature
	WScript.Echo "Size:" & objItem.Size
	WScript.Echo "Status:" & objItem.Status
	WScript.Echo "StatusInfo:" & objItem.StatusInfo
	WScript.Echo "SystemCreationClassName:" & objItem.SystemCreationClassName
	WScript.Echo "SystemName:" & objItem.SystemName
	WScript.Echo "TotalCylinders:" & objItem.TotalCylinders
	WScript.Echo "TotalHeads:" & objItem.TotalHeads
	WScript.Echo "TotalSectors:" & objItem.TotalSectors
	WScript.Echo "TotalTracks:" & objItem.TotalTracks
	WScript.Echo "TracksPerCylinder:" & objItem.TracksPerCylinder
	WScript.Echo ""
	WScript.Echo "########"
	WScript.Echo ""
Next