You are here:
ActiveXperts.com > ActiveXperts Network Monitor > WindowsManagement > Scripts > Computer Management > Computer Hardware
Quicklinks
NOTE: ActiveXperts Network Monitor ships with a large collection of VBScript scripts to monitor any aspect of your network. Most VBScript scripts also have a PowerShell implementation. Download Now »
On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_BaseBoard")
For Each objItem in colItems
For Each strOption in objItem.ConfigOptions
Wscript.Echo "Configuration Option: " & strOption
Next
Wscript.Echo "Depth: " & objItem.Depth
Wscript.Echo "Description: " & objItem.Description
Wscript.Echo "Height: " & objItem.Height
Wscript.Echo "Hosting Board: " & objItem.HostingBoard
Wscript.Echo "Hot Swappable: " & objItem.HotSwappable
Wscript.Echo "Manufacturer: " & objItem.Manufacturer
Wscript.Echo "Model: " & objItem.Model
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "Other Identifying Information: " & objItem.OtherIdentifyingInfo
Wscript.Echo "Part Number: " & objItem.PartNumber
Wscript.Echo "Powered On: " & objItem.PoweredOn
Wscript.Echo "Product: " & objItem.Product
Wscript.Echo "Removable: " & objItem.Removable
Wscript.Echo "Replaceable: " & objItem.Replaceable
Wscript.Echo "Requirements Description: " & objItem.RequirementsDescription
Wscript.Echo "Requires DaughterBoard: " & objItem.RequiresDaughterBoard
Wscript.Echo "Serial Number: " & objItem.SerialNumber
Wscript.Echo "SKU: " & objItem.SKU
Wscript.Echo "Slot Layout: " & objItem.SlotLayout
Wscript.Echo "Special Requirements: " & objItem.SpecialRequirements
Wscript.Echo "Tag: " & objItem.Tag
Wscript.Echo "Version: " & objItem.Version
Wscript.Echo "Weight: " & objItem.Weight
Wscript.Echo "Width: " & objItem.Width
Next
On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_Bus")
For Each objItem in colItems
Wscript.Echo "Bus Number: " & objItem.BusNum
Wscript.Echo "Bus Type: " & objItem.BusType
Wscript.Echo "Description: " & objItem.Description
Wscript.Echo "Device ID: " & objItem.DeviceID
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "PNP Device ID: " & objItem.PNPDeviceID
Next
On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_IRQResource")
For Each objItem in colItems
Wscript.Echo "Availability: " & objItem.Availability
Wscript.Echo "Hardware: " & objItem.Hardware
Wscript.Echo "IRQ Number: " & objItem.IRQNumber
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "Trigger Level: " & objItem.TriggerLevel
Wscript.Echo "Trigger Type: " & objItem.TriggerType
Wscript.Echo
Next
On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_ParallelPort",,48)
For Each objItem in colItems
Wscript.Echo "Availability: " & objItem.Availability
For Each strCapability in objItem.Capabilities
Wscript.Echo "Capability: " & strCapability
Next
Wscript.Echo "Description: " & objItem.Description
Wscript.Echo "Device ID: " & objItem.DeviceID
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "OS Auto Discovered: " & objItem.OSAutoDiscovered
Wscript.Echo "PNP Device ID: " & objItem.PNPDeviceID
Wscript.Echo "Protocol Supported: " & objItem.ProtocolSupported
Next
On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_PhysicalMemory",,48)
For Each objItem in colItems
Wscript.Echo "Bank Label: " & objItem.BankLabel
Wscript.Echo "Capacity: " & objItem.Capacity
Wscript.Echo "Data Width: " & objItem.DataWidth
Wscript.Echo "Description: " & objItem.Description
Wscript.Echo "Device Locator: " & objItem.DeviceLocator
Wscript.Echo "Form Factor: " & objItem.FormFactor
Wscript.Echo "Hot Swappable: " & objItem.HotSwappable
Wscript.Echo "Manufacturer: " & objItem.Manufacturer
Wscript.Echo "Memory Type: " & objItem.MemoryType
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "Part Number: " & objItem.PartNumber
Wscript.Echo "Position In Row: " & objItem.PositionInRow
Wscript.Echo "Speed: " & objItem.Speed
Wscript.Echo "Tag: " & objItem.Tag
Wscript.Echo "Type Detail: " & objItem.TypeDetail
Next
On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_Processor")
For Each objItem in colItems
Wscript.Echo "Address Width: " & objItem.AddressWidth
Wscript.Echo "Architecture: " & objItem.Architecture
Wscript.Echo "Availability: " & objItem.Availability
Wscript.Echo "CPU Status: " & objItem.CpuStatus
Wscript.Echo "Current Clock Speed: " & objItem.CurrentClockSpeed
Wscript.Echo "Data Width: " & objItem.DataWidth
Wscript.Echo "Description: " & objItem.Description
Wscript.Echo "Device ID: " & objItem.DeviceID
Wscript.Echo "Ext Clock: " & objItem.ExtClock
Wscript.Echo "Family: " & objItem.Family
Wscript.Echo "L2 Cache Size: " & objItem.L2CacheSize
Wscript.Echo "L2 Cache Speed: " & objItem.L2CacheSpeed
Wscript.Echo "Level: " & objItem.Level
Wscript.Echo "Load Percentage: " & objItem.LoadPercentage
Wscript.Echo "Manufacturer: " & objItem.Manufacturer
Wscript.Echo "Maximum Clock Speed: " & objItem.MaxClockSpeed
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "PNP Device ID: " & objItem.PNPDeviceID
Wscript.Echo "Processor Id: " & objItem.ProcessorId
Wscript.Echo "Processor Type: " & objItem.ProcessorType
Wscript.Echo "Revision: " & objItem.Revision
Wscript.Echo "Role: " & objItem.Role
Wscript.Echo "Socket Designation: " & objItem.SocketDesignation
Wscript.Echo "Status Information: " & objItem.StatusInfo
Wscript.Echo "Stepping: " & objItem.Stepping
Wscript.Echo "Unique Id: " & objItem.UniqueId
Wscript.Echo "Upgrade Method: " & objItem.UpgradeMethod
Wscript.Echo "Version: " & objItem.Version
Wscript.Echo "Voltage Caps: " & objItem.VoltageCaps
Next
On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_SerialPort",,48)
For Each objItem in colItems
Wscript.Echo "Binary: " & objItem.Binary
Wscript.Echo "Description: " & objItem.Description
Wscript.Echo "Device ID: " & objItem.DeviceID
Wscript.Echo "Maximum Baud Rate: " & objItem.MaxBaudRate
Wscript.Echo "Maximum Input Buffer Size: " & objItem.MaximumInputBufferSize
Wscript.Echo "Maximum Output Buffer Size: " & objItem.MaximumOutputBufferSize
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "OS Auto Discovered: " & objItem.OSAutoDiscovered
Wscript.Echo "PNP Device ID: " & objItem.PNPDeviceID
Wscript.Echo "Provider Type: " & objItem.ProviderType
Wscript.Echo "Settable Baud Rate: " & objItem.SettableBaudRate
Wscript.Echo "Settable Data Bits: " & objItem.SettableDataBits
Wscript.Echo "Settable Flow Control: " & objItem.SettableFlowControl
Wscript.Echo "Settable Parity: " & objItem.SettableParity
Wscript.Echo "Settable Parity Check: " & objItem.SettableParityCheck
Wscript.Echo "Settable RLSD: " & objItem.SettableRLSD
Wscript.Echo "Settable Stop Bits: " & objItem.SettableStopBits
Wscript.Echo "Supports 16-Bit Mode: " & objItem.Supports16BitMode
Wscript.Echo "Supports DTRDSR: " & objItem.SupportsDTRDSR
Wscript.Echo "Supports Elapsed Timeouts: " & objItem.SupportsElapsedTimeouts
Wscript.Echo "Supports Int Timeouts: " & objItem.SupportsIntTimeouts
Wscript.Echo "Supports Parity Check: " & objItem.SupportsParityCheck
Wscript.Echo "Supports RLSD: " & objItem.SupportsRLSD
Wscript.Echo "Supports RTSCTS: " & objItem.SupportsRTSCTS
Wscript.Echo "Supports Special Characters: " & objItem.SupportsSpecialCharacters
Wscript.Echo "Supports XOn XOff: " & objItem.SupportsXOnXOff
Wscript.Echo "Supports XOn XOff Setting: " & objItem.SupportsXOnXOffSet
Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set objProcessor = objWMIService.Get("win32_Processor='CPU0'")
If objProcessor.Architecture = 0 Then
Wscript.Echo "This is an x86 computer."
ElseIf objProcessor.Architecture = 1 Then
Wscript.Echo "This is a MIPS computer."
ElseIf objProcessor.Architecture = 2 Then
Wscript.Echo "This is an Alpha computer."
ElseIf objProcessor.Architecture = 3 Then
Wscript.Echo "This is a PowerPC computer."
ElseIf objProcessor.Architecture = 6 Then
Wscript.Echo "This is an ia64 computer."
Else
Wscript.Echo "The computer type could not be determined."
End If
strComputer = "."
Set objWMIService = GetObject("winmgmts:" _
& "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colMice = objWMIService.ExecQuery _
("Select * from Win32_PointingDevice")
For Each objMouse in colMice
Wscript.Echo "Hardware Type: " & objMouse.HardwareType
Wscript.Echo "Number of Buttons: " & objMouse.NumberOfButtons
Wscript.Echo "Status: " & objMouse.Status
Wscript.Echo "PNP Device ID: " & objMouse.PNPDeviceID
Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:" _
& "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colBIOS = objWMIService.ExecQuery _
("Select * from Win32_BIOS")
For each objBIOS in colBIOS
Wscript.Echo "Build Number: " & objBIOS.BuildNumber
Wscript.Echo "Current Language: " & objBIOS.CurrentLanguage
Wscript.Echo "Installable Languages: " & objBIOS.InstallableLanguages
Wscript.Echo "Manufacturer: " & objBIOS.Manufacturer
Wscript.Echo "Name: " & objBIOS.Name
Wscript.Echo "Primary BIOS: " & objBIOS.PrimaryBIOS
Wscript.Echo "Release Date: " & objBIOS.ReleaseDate
Wscript.Echo "Serial Number: " & objBIOS.SerialNumber
Wscript.Echo "SMBIOS Version: " & objBIOS.SMBIOSBIOSVersion
Wscript.Echo "SMBIOS Major Version: " & objBIOS.SMBIOSMajorVersion
Wscript.Echo "SMBIOS Minor Version: " & objBIOS.SMBIOSMinorVersion
Wscript.Echo "SMBIOS Present: " & objBIOS.SMBIOSPresent
Wscript.Echo "Status: " & objBIOS.Status
Wscript.Echo "Version: " & objBIOS.Version
For i = 0 to Ubound(objBIOS.BiosCharacteristics)
Wscript.Echo "BIOS Characteristics: " & _
objBIOS.BiosCharacteristics(i)
Next
Next
On Error Resume Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:\\" & strComputer & "\root\cimv2")
Set colItems = objWMIService.ExecQuery("Select * from Win32_POTSModem")
For Each objItem in colItems
Wscript.Echo "Attached To: " & objItem.AttachedTo
Wscript.Echo "Blind Off: " & objItem.BlindOff
Wscript.Echo "Blind On: " & objItem.BlindOn
Wscript.Echo "Compression Off: " & objItem.CompressionOff
Wscript.Echo "Compression On: " & objItem.CompressionOn
Wscript.Echo "Configuration Manager Error Code: " & _
objItem.ConfigManagerErrorCode
Wscript.Echo "Configuration Manager User Configuration: " & _
objItem.ConfigManagerUserConfig
Wscript.Echo "Configuration Dialog: " & objItem.ConfigurationDialog
Wscript.Echo "Country Selected: " & objItem.CountrySelected
Wscript.Echo "DCB: "
For Each objElement In objItem.DCB
WScript.Echo vbTab & objElement
Next
Wscript.Echo "Default: "
For Each objElement In objItem.Default
WScript.Echo vbTab & objElement
Next
Wscript.Echo "Device ID: " & objItem.DeviceID
Wscript.Echo "Device Type: " & objItem.DeviceType
Wscript.Echo "Driver Date: " & objItem.DriverDate
Wscript.Echo "Error Control Forced: " & objItem.ErrorControlForced
Wscript.Echo "Error Control Off: " & objItem.ErrorControlOff
Wscript.Echo "Error Control On: " & objItem.ErrorControlOn
Wscript.Echo "Flow Control Hard: " & objItem.FlowControlHard
Wscript.Echo "Flow Control Off: " & objItem.FlowControlOff
Wscript.Echo "Flow Control Soft: " & objItem.FlowControlSoft
Wscript.Echo "Inactivity Scale: " & objItem.InactivityScale
Wscript.Echo "Inactivity Timeout: " & objItem.InactivityTimeout
Wscript.Echo "Index: " & objItem.Index
Wscript.Echo "Maximum Baud Rate To SerialPort: " & _
objItem.MaxBaudRateToSerialPort
Wscript.Echo "Model: " & objItem.Model
Wscript.Echo "Modem Inf Path: " & objItem.ModemInfPath
Wscript.Echo "Modem Inf Section: " & objItem.ModemInfSection
Wscript.Echo "Modulation Bell: " & objItem.ModulationBell
Wscript.Echo "Modulation CCITT: " & objItem.ModulationCCITT
Wscript.Echo "Name: " & objItem.Name
Wscript.Echo "PNP Device ID: " & objItem.PNPDeviceID
Wscript.Echo "Port SubClass: " & objItem.PortSubClass
Wscript.Echo "Prefix: " & objItem.Prefix
Wscript.Echo "Properties: "
For Each objElement In objItem.Properties
WScript.Echo vbTab & objElement
Next
Wscript.Echo "Provider Name: " & objItem.ProviderName
Wscript.Echo "Pulse: " & objItem.Pulse
Wscript.Echo "Reset: " & objItem.Reset
Wscript.Echo "Responses Key Name: " & objItem.ResponsesKeyName
Wscript.Echo "Speaker Mode Dial: " & objItem.SpeakerModeDial
Wscript.Echo "Speaker Mode Off: " & objItem.SpeakerModeOff
Wscript.Echo "Speaker Mode On: " & objItem.SpeakerModeOn
Wscript.Echo "Speaker Mode Setup: " & objItem.SpeakerModeSetup
Wscript.Echo "Speaker Volume High: " & objItem.SpeakerVolumeHigh
Wscript.Echo "Speaker Volume Info: " & objItem.SpeakerVolumeInfo
Wscript.Echo "Speaker Volume Low: " & objItem.SpeakerVolumeLow
Wscript.Echo "Speaker Volume Med: " & objItem.SpeakerVolumeMed
Wscript.Echo "Status Info: " & objItem.StatusInfo
Wscript.Echo "Terminator: " & objItem.Terminator
Wscript.Echo "Tone: " & objItem.Tone
Wscript.Echo
Next
strComputer = "."
Set objWMIService = GetObject("winmgmts:" _
& "{impersonationLevel=impersonate}!\\" & strComputer & "\root\cimv2")
Set colSettings = objWMIService.ExecQuery _
("Select * from Win32_OperatingSystem")
For Each objOperatingSystem in colSettings
Wscript.Echo "OS Name: " & objOperatingSystem.Name
Wscript.Echo "Version: " & objOperatingSystem.Version
Wscript.Echo "Service Pack: " & _
objOperatingSystem.ServicePackMajorVersion _
& "." & objOperatingSystem.ServicePackMinorVersion
Wscript.Echo "OS Manufacturer: " & objOperatingSystem.Manufacturer
Wscript.Echo "Windows Directory: " & _
objOperatingSystem.WindowsDirectory
Wscript.Echo "Locale: " & objOperatingSystem.Locale
Wscript.Echo "Available Physical Memory: " & _
objOperatingSystem.FreePhysicalMemory
Wscript.Echo "Total Virtual Memory: " & _
objOperatingSystem.TotalVirtualMemorySize
Wscript.Echo "Available Virtual Memory: " & _
objOperatingSystem.FreeVirtualMemory
Wscript.Echo "OS Name: " & objOperatingSystem.SizeStoredInPagingFiles
Next
Set colSettings = objWMIService.ExecQuery _
("Select * from Win32_ComputerSystem")
For Each objComputer in colSettings
Wscript.Echo "System Name: " & objComputer.Name
Wscript.Echo "System Manufacturer: " & objComputer.Manufacturer
Wscript.Echo "System Model: " & objComputer.Model
Wscript.Echo "Time Zone: " & objComputer.CurrentTimeZone
Wscript.Echo "Total Physical Memory: " & _
objComputer.TotalPhysicalMemory
Next
Set colSettings = objWMIService.ExecQuery _
("Select * from Win32_Processor")
For Each objProcessor in colSettings
Wscript.Echo "System Type: " & objProcessor.Architecture
Wscript.Echo "Processor: " & objProcessor.Description
Next
Set colSettings = objWMIService.ExecQuery _
("Select * from Win32_BIOS")
For Each objBIOS in colSettings
Wscript.Echo "BIOS Version: " & objBIOS.Version
Next